|ShilNepal Editorial
Lab report sheet beside a tin of Himalayan shilajit resin

"Lab tested" is on a lot of supplement tins. It is true of a sample sent to any lab for any test, and it tells you very little on its own. This guide explains what Australia's laboratory accreditation system actually certifies, why the phrase "scope of accreditation" is the part worth understanding, how you can look a lab up yourself, and how to read our own lab page in that light, including a detail on it that we think you should know about.

Key takeaways

  • NATA, the National Association of Testing Authorities, accredits Australian laboratories. Testing labs are accredited against the international standard ISO/IEC 17025.
  • Accreditation applies to the methods and procedures on a lab's scope of accreditation, not to everything the lab does.
  • NATA says its endorsement on a report is not permitted for testing outside the scope of accreditation.
  • Accreditation speaks to a lab's competence. It says nothing about what a product does for a person.

Three things "lab tested" can mean

What the label says What you can actually check How much it tells you
"Lab tested" Nothing. No lab, no batch, no report. Almost nothing
A named lab and a report for your batch The lab, the batch number, the tests and the results A lot, if you can read the report
A report from an accredited lab, with the tests on it inside that lab's scope Everything above, plus whether the method itself was independently assessed The strongest signal available to a buyer

The middle row is already far better than most labels. The third row is the one this article is about.

What accreditation certifies

NATA describes accreditation as the way it recognises organisations that perform specific technical and scientific activities, including testing and calibration. Laboratories are accredited against ISO/IEC 17025, which NATA describes as the standard used to deem a lab technically competent for the methods and procedures listed on its scope of accreditation. The current version is ISO/IEC 17025:2017, replacing a 2005 edition.

The standard covers the things that make a number trustworthy: whether the method is valid, whether staff are competent, whether equipment is traceable to measurement standards, how samples are handled, quality control, and how results are reported. NATA also says its accreditation is recognised and accepted globally, which is part of why accredited results travel between countries without being repeated.

The laboratory is accredited It has been assessed as competent. That is the whole lab, but not every test. Scope of accreditation The methods listed for that lab Test A: inside the scope, covered Test B: inside the scope, covered Outside the scope Test C: the lab can run it, but accreditation does not cover it
Figure 1. An accredited lab can run tests that are not on its scope. The scope, not the lab's name, decides which results carry accreditation.

Scope: the detail that matters

NATA's page on test reports ties its endorsement to scope. Accredited organisations are encouraged to put the NATA endorsement on reports for activities covered by their scope of accreditation. The use of the endorsement is not permitted on reports of testing outside that scope, with exceptions that must first be discussed with NATA. Subcontracted results must be clearly identified.

In practice this gives you a simple reading rule. If a report carries the NATA endorsement, the testing on it is within the lab's accredited scope. If a report mixes tests, some may be inside the scope and some outside, and a careful lab says which. A mixed report is not a bad report. It just means you should not assume the accreditation logo at the top covers every line below it.

We did not find a single plain-language definition of "scope of accreditation" on NATA's pages, so this is our reading of how its pages fit together. If the detail matters to a purchase decision, ask the seller or the lab which results are in scope.

How to check a lab yourself

NATA publishes a searchable directory of accredited organisations. The search page lets you work with these options:

  • 1Search by business name or accreditation number, or by a combination of fields.
  • 2Filter by accreditation standard, product or material type, determination, technique or test standard.
  • 3Put a phrase in double quotation marks to match it exactly, for example "heavy metals".
  • 4Filter by state or territory, and by status: active, suspended or withdrawn.

The directory is at nata.com.au, under "Search accredited organisations". We have described the options from the search page. We did not run a search for this article, so check the results layout yourself.

What accreditation does not tell you

  • It does not say anything about what a product does for a person. A clean heavy metals result means those metals were below the reported limits in that sample, nothing more.
  • It covers one batch. A new batch needs its own report. See how to read a product label.
  • It does not mean the seller wrote the report accurately into their marketing. Read the report, not the summary of it.

Our own report, read honestly

ShilNepal sells shilajit, so we have an interest in how this reads. Here is what our lab results page says. Batch #1093 was tested by Eurofins Food Australia at its Dandenong South facility, report AR-25-NV-025372-01, issued 13 November 2025, for heavy metals. The page also says, in a line taken from the report, that some tests are outside the laboratory's accreditation scope. It describes this as standard laboratory disclosure.

We think that line is worth reading carefully, not skipping past. By the reading rule above, it means the accreditation does not extend to every test on the report. Our results page does not break down which results sit inside or outside the scope, and we have not done that here either. If that distinction matters to you, email us at info@shilnepal.com, and you can also ask the laboratory.

The report also shows why a related term matters. For mercury it reports less than 0.002 mg/kg, described as not detected at or above the laboratory's limit of quantification. That is a limit, not a zero. A number written with "less than" tells you the lab could not measure above that floor.

Lab results, batch #1093

Read the report and judge it yourself

Our results page publishes the batch #1093 report details, the measured values and how they compare with Australian benchmark limits.

Open the lab results page

A lab report describes one batch only.

FAQ

What is NATA?

NATA is the National Association of Testing Authorities, the body that accredits Australian laboratories, along with calibration, inspection and other technical organisations.

What is ISO/IEC 17025?

It is the international standard testing and calibration laboratories are accredited against. NATA says it is the standard used to deem a lab technically competent for the methods on its scope of accreditation.

Does "NATA accredited" mean every test on a report is covered?

No. Accreditation applies to the methods on the lab's scope. NATA says its endorsement is not permitted on reports of testing outside that scope.

Does an accredited result mean a supplement is safe or works?

No. It speaks to the lab's competence in measuring what it measured, not to what a product does in the body.

Sources

  1. NATA. What is accreditation? nata.com.au/accreditation.
  2. NATA. Testing and calibration (ISO/IEC 17025) accreditation. nata.com.au/accreditation/laboratory-accreditation-iso-iec-17025.
  3. NATA. NATA test reports explained. nata.com.au/accreditation/nata-test-reports-explained.
  4. NATA. Search accredited organisations. nata.com.au/find-organisation.
  5. ShilNepal. Lab test results, batch #1093. shilnepal.com/pages/lab-test-results.

We did not read the text of ISO/IEC 17025 itself, which is sold by ISO. Statements about the standard come from NATA's description of it.

Related Reading